Proven PerformanceMODEL 8000 IPG, ITEM # 165920Industrial Portable Generator M165920FOWNER’S MANUALAny Questions, Comments, or Problems?Call Cus
95. When engine starts, move choke lever to RUNposition.6. Loads may now be connected to generator.STOPPING1. Disconnect all loads to generator.2. Pl
10 TROUBLESHOOTINGProblem Possible Causes Possible RemediesEngine will not start. a) Low oil level.b) Fouled spark plug.c) Out of fuel.d) St
1THANK YOUThank you for purchasing a NorthStar Industrial Portable Series Generator. Your machine isdesigned for long life, dependability, and the to
2 SPECIFICATIONSItem Number 165920Maximum Output 8000 Watts (W)Continuous Output 6600 Watts (W)Voltage 120 / 240 Volt (V)Phase Single phase (4-w
3Figure 1 (Ref. 1-7) 00576Ref. DescriptionRef. Description1 Air Cleaner 8 Generator Head2 Starting/Stopping Instructions 9 Battery Box3 Oi
4GENERATOR FEATUREReference 1 - Air Cleaner. Refer to your Hondaengine manual for air cleaner care.Reference 2 - Starting/Stopping Instructions.Refere
5• Reference 23 - One straight-blade 120V receptaclecapable of drawing 50 amp, NEMA 5-50R. Thisaccepts a NEMA 5-50P plug.• Reference 24 - One duplex
6ALWAYS remove the spark plug or spark plug wirebefore working on the engine or generator, to preventaccidental starting.ALWAYS provide adequate venti
7are the easiest to start and require 1.5 to 2.5 times more tostart than to run.Most fractional motors take about the same amount ofcurrent to run the
8Toaster 1000Vacuum cleaner 250VCR 70Water Heater 3000Weed Trimmer 500(a) Hard-starting motors require 3 to 5 times the ratedrunning watts.(b) These l